Jackwell Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Lai Jenny
  • Company Name : Jackwell Technology Co., Ltd.
  • Tel : 86-769-22687008
  • Fax : 86-769-22687018
  • Address : Guangdong,Dongguan,No.25, Guanhui Plaza, Dongzhong Road, Dongguan City
  • Country/Region : China
  • Zip : 523000

100KVA caterpillar generator

100KVA caterpillar generator
Product Detailed
Related Categories:Diesel Generators
100KVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility.

100KVA Caterpillar generator set

GEP110-2

Diesel Generator Set

Exclusively from your Caterpillar

®

Output Ratings100.0 kVA

380-415V,50Hz

480V, 60 Hz

0.8

Ratings at power factor.

Technical Data

Engine Techncial Data

Physical Data

Lubrication system

4.4 (268.5)

Displacement:

l (cu.in)

-Standby:

103.0 (138.0)

117.5 (158.0)

105.0 (4.1)/127.0 (5.0)

Bore/Stroke

: mm (in)

93.6 (126.0)

106.8 (143.0)

-Prime:

1.51 (5160)

Moment of Inertia:

kg m² (lb. in²)

BMEP:

kPa (psi)

1873.0 (271.7)

1781.0 (258.3)

Engine Electrical System:

-Standby:

12/Negative

-Voltage/Ground:

1702.0 (246.9)

1619.0 (234.8)

-Prime:

65

8.2

13.8

-Battery Charger Amps:

Regenerative Power:

kW

500 (1102)

Weight:

kg (lb)

- Dry:

520 (1146)

- Wet:

Fuel System

Replaceable Element

Fuel Filter Type:

Air System

50 Hz

60 Hz

Recommended Fuel:

Class A2 Diesel

Fuel Consumption:

l/hr (US gal/hr)

Replaceable Element

Air Filter Type:

110%

Load

100%

Load

75%

Load

50%

Load

Combustion Air Flow:

6.3 (221)

7.8 (275)

m³/min (cfm)

-Standby:

Prime

6.0 (212)

7.7 (273)

-Prime:

50 Hz

24.1 (6.4)

21.9 (5.8)

16.6 (4.4)

11.7 (3.1)

Max. Combustion Air Intake

60 Hz

29.3 (7.7)

26.3 (6.9)

19.9 (5.3)

14.2 (3.8)

8.0 (32.1)

8.0 (32.1)

Restriction:

kPa (in H

2

O)

Radiator Cooling Air Flow:

Standby

187.8 (6632)

244.2 (8624)

m³/min (cfm)

24.1 (6.4)

18.2 (4.8)

12.6 (3.3)

50 Hz

External Restriction to

29.3 (7.7)

21.9 (5.8)

15.4 (4.1)

60 Hz

125 (0.5)

125 (0.5)

Cooling Air Flow:

Pa (in H

2

O)

(based on diesel fuel with a specific gravity of 0.85 and conforming to

BS2869, Class A2)

Exhaust System

50 Hz

60 Hz

Cooling System

50 Hz

60 Hz

Level 1

Cooling System Capacity:

Silencer Type:

SD50 (1)

17.5 (4.6)

17.5 (4.6)

l (US gal)

Silencer Noise Reduction

Centrifugal

Water Pump Type:

Pressure Drop Across

2.10 (0.620)

3.56 (1.051)

Heat Rejected to Water &

Silencer System:

kPa (in Hg)

Lube Oil:

kW (Btu/min)

Silencer Noise Reduction

50.7 (2883)

62.5 (3554)

22

17

-Standby:

Level:

dB

46.1 (2622)

56.9 (3236)

-Prime:

Max. Allowable Back

18.0 (5.3)

15.0 (4.4)

Pressure:

kPa (in. Hg)

Heat Radiation to Room:

7.5 (427)

9.2 (523)

kW (Btu/min)

-Standby:

Exhaust Gas Flow:

6.8 (387)

8.4 (478)

16.3 (576)

20.4 (720)

-Prime:

m³/min (cfm)

-Standby:

2.8 (3.8)

4.8 (6.4)

15.2 (537)

18.4 (650)

Radiator Fan Load:

kW (hp)

-Prime:

Exhaust Gas Temperature:

°C (°F)

543 (1009)

574 (1065)

m³/min (cfm)

-Standby:

514 (957)

517 (963)

-Prime:

Cooling system designed to operate in ambient conditions up to 50°C

(122°F). Contact your local Olympian dealer for power ratings at specific

site conditions.

100KVA caterpillar generator



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.